Configuration

The pulses generated are configurable; the properties described here can be adjusted.

Pulse polarity

Alternating Bipolar (alternating positive-negative)
Non-alternating Unipolar

With an alternating pulse, the plus and min is reversed with every subsequent pulse. For example, if the first pulse is +24V, the second pulse is -24V, the third is +24V again, and so on.

Non-alternating pulses do not have this reversal.

The majority of clocks use alternating pulses; English movements in particular use non-alternating pulses by default.

Pulse frequency

A pulse driver does one thing: give pulses. But how quickly in succession?

60 seconds
One pulse every full minute
30 seconds
Two pulses per minute
15 seconds
Four pulses per minute
1 second *
60 pulses per minute (seconds clock)

*) With a switch on the pulse driver, you can also always select one pulse per second, whichever frequency configuration (60/30/15) is set. The manual explains how.

Pulse length

How long does a pulse remain on to send electrical energy through the circuit?

Configured set
Selection via DIP switch
Small 50, 100, 150, 300 milliseconds
Medium 150, 200, 250, 300 milliseconds
Large 500, 700, 900, 1000 milliseconds
XL 1200, 1400, 1800, 2000 milliseconds
XXL 5, 6, 7, 8 seconds
3XL 10, 20, 30, 40 seconds

Using switches on the pulse generator, one value at a time from the configured set (S to 3XL) can be selected. See the manual for details.

The longer the pulse, the more energy is supplied to move the hands one step. Every clock is slightly different and may require a different pulse length. If the hands are not advanced properly, or not always properly, with every pulse, increase the pulse length.

A shorter pulse length is beneficial for battery life.

Changing the configuration

The basic configuration can be adjusted on the latest generation of pulse generators via the configuration menu.


None of the aforementioned configurations fit?

Send us a message! We would be happy to help find a solution for this special clock.