Pulse configuration

Running the pulse driver with different pulse lengths

The step-by-step guide below changes one setting of the basic configuration.
In 5 steps, the pulse length is changed from its current value to Large.

Configured set
Selection via DIP switch
Small 50, 100, 150, 300 milliseconds
Medium 150, 200, 250, 300 milliseconds
Large 500, 700, 900, 1000 milliseconds
XL 1200, 1400, 1800, 2000 milliseconds
XXL 5, 6, 7, 8 seconds
3XL 10, 20, 30, 40 seconds

One of the values from the configured set (S to 3XL) can be activated via the DIP switches on the pulse generator.

This step-by-step guide can also be used to set one of the other sets. To do so, use an alternative step 5, as shown in the last paragraph below.

Lost track halfway through the step-by-step guide? No problem: just disconnect the power supply and go back to the start!
 

This configuration can only be adjusted for pulse generators with version number S3. Do you own an S1 or S2? Then please contact us.

Starting up in test mode

Step 1

Disconnect the (battery) connector or USB.

Step 2

Hold down TIK and reconnect the power supply at the same time.

The pulse generator is now starting up in test mode, recognizable by:

  • A pulse every second
  • LED flashes in sync with the pulse

Proceed to configuration mode

Step 3

Set DIP switch to 2, 3, and 4 ON

7 sec

Hold down TIK (for approx. 7 seconds) until the LED has flashed very rapidly for one second as confirmation.

The pulse generator is now in configuration mode, recognizable by:

  • LED on with one short cyclical interruption
  • No pulses

If the TIK button is not used for more than 30 seconds, the pulse generator will automatically configuration mode exit by restarting.

Set pulse length

Step 4

Set DIP switch: all to OFF
(= selection: set pulse length)

7 sec

Hold down TIK, until the LED has blinked very rapidly as confirmation.

  • The LED remains on for a long time after this, with two short interruptions each time.

Step 5

Set DIP switch: only 3 ON
(= setting selection: Large)
7 sec

Hold down TIK, until the LED out / On / out go.

The new setting has now been saved. and the pulse generator restarts. From now on, the new pulse length will always be used!

Step 5 alternative

By using one of these DIP switch values in Step 5 , different pulse lengths can be configured:

Small
Medium
Large
XL
XXL
3XL