User manual
220mA pulse driver
220mA pulse driver
-
Connections
-
Settings (DIP switch)
-
TICK button
-
Batteries dead
-
Technical details
-
Changing the configuration
The 220mA pulse driver has a current-controlled pulse output. This provides pulses with a fixed current intensity.
| Pulse control | 220 milliamperes |
| Polarity 1 | Unipolar (non-alternating) |
| Frequency 1 | 1 pulse every 30 seconds (or 1 per second) |
| Assets | For 1 or 2 timepieces (double-sided clock) |
| Size | 60 x 37 x 18 mm (LxWxH) |
(1) This manual describes operation with the 'standard' basic configuration of this pulse generator. This configuration can be elected when ordering. The basic configuration can be adjusted at a later time via the configuration menu. In the last section you can read how this works.
Connections
Right - Clock pulses
Clamp screw connection for the wires to the clock movement.
The cable to the clock may be longer than the supplied terminals. Tested up to a length of 10 meters.
Links - Nutrition
The pulse generator can be connected via both a DC jack and a micro-USB.
- DC Jack connection Ø 5.5 x 2.1 mm (3.5 – 6.0V DC)
- Micro-USB connector (5V DC)
The battery box is equipped with a DC Jack connector.
Please note, with the battery case and USB connected simultaneously only used the battery box as a power supply.
Institutions
With the DIP switches, the pulse length and the pulse frequency to set.
After a setting has been changed, the pulse generator will need to be restarted to activate it.
How: restart
Pulsefrequency
Dip switch 2
One pulse every 30 seconds (pulse frequency).
One pulse per second for second hand control:
Pulselength
Of dip-swich 3 and 4 can the time be set for how long a pulse remains 'on'.
150 milliseconds (best for batteries):
200 milliseconds
250 milliseconds
300 milliseconds
Switch 1
Dip switch 1 has no function on this current-controlled pulse generator.
What does the TIK button do?
Depending on the settings, the Tap button has different functions.
For institution: One pulse per pulse frequency
TICK = Generate pulse
Press the button to generate a pulse. The LED flashes briefly.
To be used to the to set the clock to the time. With each manual pulse, the internal second time of the pulse generator is reset to 0.
Tip: Press and hold the button for a whole series of pulses.
For institution: One pulse per second
TICK = Pause / Start
With the push of a button, the second pulse is interrupted or re-enabled (play/pause).
In pause mode, the LED flashes briefly and regularly; play: LED is off.
Batteries dead
The pulse generator checks the supply voltage level at two points in time.
- Startup: once when switching on the pulse generator
- TICK button: whenever a manual pulse is generated
When the supply voltage is (too) low, the LED flashes 3 times in a warning pattern.
It is possible that the clock will still work normally, but the batteries will run out completely in the foreseeable future.
With dead batteries, it may happen that the pulse generator still functions, but the clock will no longer strike.
Technical details
| Pulse generator dimensions | 65 x 40 x 20 mm (LxWxH) |
| Battery box dimensions | 70 x 65 x 20 mm (LxWxH) |
| Batteries (battery box) | 4 pieces 1.5V AA (penlight) |
| Precision time display | Within a bandwidth of -4.0 to +4.0 seconds per month on average per year |
| Supply voltage | 3.5 – 6.0 Volts DC |
| Power connector 1 | DC Jack Ø 5.5 x 2.1 mm |
| Power connector 2 | Micro USB Type B |
| Pulse output | 220mA (±5mA) @ variable voltage min +/- 0.9V – max +/- 3.5V |
| Pulse output connection | Terminal connection for wire gauge 0.129 – 1.31 mm² (26-16 AWG) |
| Environment | Indoor use |
Changing the configuration
The basic configuration can be adjusted on the latest generation of pulse generators via the configuration menu.
- For example, do you need one pulse every 30 seconds instead of one pulse per minute? Follow the step-by-step plan. pulse frequency to adjust:
Change pulse frequency base configuration
- Need longer or shorter pulses? Follow the step-by-step plan to use other pulse lengths to configure:
Change pulse length base configuration
- Follow the step-by-step plan below to the polarity (alternating) to adjust the pulses:
Change pulse polarity base configuration